Applies To

Projecta PW2700

2700W 12V Pro-Wave Pure Sine Wave Inverter

Pro-Wave

Overview

The Projecta PW2700 converts 12V DC battery power into 240V AC, 50Hz output for running compatible 240V appliances away from mains power. This model provides 2700W continuous, 3240W surge for approx. 10 minutes, 5400W peak for approx. 1 second and uses Pure sine wave output.

Always confirm the appliance power requirement, start-up surge, battery capacity, cable size and installation requirements before use.

Key Specifications

Input: 12V DC, 11–14.5V; rated current 265A, max 318A

Output: 2700W continuous, 3240W surge for approx. 10 minutes, 5400W peak for approx. 1 second

AC output: 240V AC, 50Hz

Waveform / type: Pure sine wave

USB output: USB-C 21W and USB-A 5V DC, 2.1A

Battery guidance: Minimum 135Ah, ideal 180Ah+

Fuse / protection: Internal fuse: 350A; recommended external fuse: 300A

Dimensions: 479 x 272 x 113 mm

Weight: 7.4 kg

Warranty: 3 years

Suitable Applications

Sensitive electronics and general 240V appliances within the inverter rating.

Camping, caravan, 4WD, canopy and touring applications.

Appliances with motors, pumps or compressors must be checked for startup surge before use.

Power Source and Battery Requirements

Use only a suitable 12V DC battery system.

Battery capacity guidance: Minimum 135Ah, ideal 180Ah+.

Ensure the battery is fully charged and in good condition before operating high loads.

High-power appliances draw very high DC current. Undersized batteries, cables or fuses can cause voltage drop, shutdown or battery damage.

Runtime guidance: Approx. 30 minutes at 2700W on a 135Ah battery.

Installation Notes

Install the unit in a dry, cool and well-ventilated location.

Keep ventilation openings clear and do not mount the unit where heat can build up.

Install the correct fuse or circuit breaker as close as practical to the battery positive terminal.

Use the cable size and installation method specified in the instruction manual.

Check polarity carefully before connecting the DC cables.

Operating Instructions

Make sure all connected appliances are switched off before turning the inverter on.

Turn the inverter on and allow it to start normally.

Connect or switch on appliances one at a time.

Do not exceed the continuous output rating or peak surge capability.

If a fault occurs, switch the unit off, remove the load, correct the cause and restart the unit.

Common Troubleshooting

The inverter turns off during operation. What should I check?

Check for overload, low battery voltage, high input voltage, over-temperature, short circuit or excessive voltage drop.

Confirm the appliance does not exceed the continuous rating or startup surge capability.

Check that the battery and cable size are suitable for the load.

If overheated, switch the inverter off, remove the load and allow it to cool for approximately 15 minutes before restarting.

The appliance will not start even though it is below the wattage rating. Why?

Inductive or capacitive appliances such as fridges, pumps, compressors and some tools can draw a much higher startup current than their running wattage.

Try a smaller load or confirm the appliance startup surge is within the inverter rating.

What do fault messages generally mean?

Low voltage or undervoltage indicates the battery voltage is too low under load.

Overvoltage indicates the input voltage is too high.

Overload or short circuit indicates the connected load must be removed or reduced.

Over-temperature indicates the inverter needs to cool before restarting.

Safety Warnings

Read the instruction manual before installation or use.

Use the inverter in a dry, cool and well-ventilated location protected from rain, water, dust and excessive heat.

Do not install the inverter in the same compartment as batteries or flammable materials.

Always use correctly sized DC cables, fuses and secure connections.

Do not connect the AC output to fixed building wiring, mains wiring, or another inverter output unless the manual specifically allows the installation and it is completed by a licensed electrician.

High AC voltage is present during operation. Do not open or service the unit unless qualified.

Reverse polarity connection can damage the inverter and may not be covered under warranty.

Warranty Information

The Projecta PW2700 is listed with a 3 years warranty under normal use. Warranty does not cover damage caused by incorrect installation, reverse polarity, misuse, modification, overload, water ingress, physical damage or failure to follow the product instructions.

Contact Support

If the issue continues after completing the troubleshooting steps, stop using the inverter and contact Projecta support.

Please provide:

Product model: PW2700

Serial number if available

Battery system voltage and battery capacity

Connected appliance type and wattage rating

Photos of the installation, fuse, cable connections and any fault display

Battery voltage reading with no load and while the appliance is connected

Description of the issue and when it occurs