The Projecta EVC2KW is a portable emergency EV charger designed for charging electric vehicles with a Type 2 charging inlet.
It is designed to plug into a standard 10A socket outlet and provide up to 2.4kW charging output. The charger automatically detects the vehicle connection status and starts charging once the EV handshake process is complete.
The EVC2KW is intended for EV charging only and is not designed for other applications.
The EVC2KW includes:
Portable emergency EV charging
Type 2 EV charging connector
10A 2.4kW charging output
230VAC input and output
5m total cable length
IP65 rainproof design
Rugged ABS enclosure
LCD display
Battery level indicator light
Mode button
Delay start timer
In-cord Control and Protection Device, IC-CPD
Automatic vehicle connection detection
Over-voltage protection
Under-voltage protection
Over-current protection
Over-temperature protection
Leakage current protection
Short-circuit protection
The EVC2KW is designed for electric vehicles with a compatible Type 2 charging inlet.
It is intended for emergency or portable EV charging from a suitable 230VAC 10A supply.
No.
The manual states the charger is only for EV charging and is not designed for other applications.
The EVC2KW is designed to plug into a 240VAC, 50Hz, 10A socket outlet.
The charger must be plugged directly into the wall socket and not through an extension cord.
The EVC2KW provides:
Rated current: 10A
Rated power: 2.4kW
Rated input voltage: 230VAC ±10%
Rated output voltage: 230VAC ±10%
Actual charging time may vary depending on the vehicle, battery size, state of charge and vehicle onboard charger limits.
Yes.
The EVC2KW includes a delay start timer.
Available delay settings:
2 hours
4 hours
6 hours
8 hours
After connecting the charger to mains power and before connecting it to the EV, press and hold the button for approximately 3 seconds to select the delay start timer.
The delay timer step can be skipped if delayed charging is not required.
Before using the EVC2KW:
Only use the charger for EV charging.
Do not use the charger if it is damaged.
Do not open any part of the charger yourself.
Do not disconnect the charger while it is actively charging.
Follow the user manual before use.
Regularly inspect the charger for visible damage.
Do not modify, retrofit or change any part of the charger.
Keep the charging cable in a clean, stable environment.
Do not use the charger near flammable gases or liquids.
Confirm the charger is being used with a 240VAC, 50Hz, 10A supply.
Do not use the charger if it fails to operate correctly.
Do not connect the 240V plug through an adapter.
Do not use an extension cord.
Plug the charger directly into a suitable wall socket.
The EVC2KW requires a suitable 230VAC / 240VAC, 50Hz, 10A socket outlet.
No.
The manual states the charger must be plugged directly into the wall socket and not through an extension cord.
No.
The manual states the 240V plug must not be connected via an adapter because high current is required.
The EVC2KW includes the following parts:
Type 2 outlet / vehicle connector
Rubber protection cover
LCD screen
Battery level indicator light
Mode button
AC plug
4.2m EV-side cable
0.8m AC-side cable
The total cable length is approximately 5m.
The delay timer must be set while the charger is connected to mains power and before it is connected to the EV.
The display can show:
Charging current
Input voltage
Charging power
Charging time
Battery charging icon
Delay start timer
Charging completed status
Error mode
The battery icon shows charging status during operation.
As charging progresses, the display indicates the charging state and charging information.
Error Mode means the charger has detected a fault.
Check the error code and follow the recommended recovery step.
Check the following:
The charger is connected directly to a 10A wall socket.
The socket has power.
The charger is not connected through an extension cord.
The charger is not connected through an adapter.
The Type 2 connector is fully inserted into the vehicle.
The vehicle is ready to accept charge.
The delay timer has not been set unintentionally.
No error message is displayed.
The plug, cable and connector are not damaged.
This may be normal before charging begins or after charging is completed.
If the charger remains at 0.0A and the vehicle is not charging, check:
The vehicle has accepted the charging session.
The Type 2 connector is properly connected.
The delay timer is not active.
The vehicle battery is not already fully charged.
No error mode is displayed.
Check the error number shown on the display.
Follow the matching recovery method in the Error Codes section.
If the same error returns, stop using the charger and contact Projecta support.
Possible causes include:
Vehicle has finished charging.
Vehicle has stopped requesting charge.
Input voltage is too low or too high.
Over-current condition.
Over-temperature protection.
Leakage current fault.
Connector or plug issue.
Supply socket issue.
Check the EV, charger display and supply connection before restarting.
Stop charging and allow the charger or plug to cool.
Check that:
The charger is connected directly to a suitable 10A socket.
The wall socket is not loose or damaged.
The plug is fully inserted.
There is no visible melting, discolouration or damage.
The charger is not covered during use.
The charger is not being used in an unsuitable environment.
Do not continue using the charger if there are signs of heat damage.
Recovery method:
Wait, then retry charging.
Recovery method:
Disconnect the charging plug, then retry charging.
Recovery method:
Disconnect the charging plug, then retry charging.
Recovery method:
Disconnect the charging plug, then retry charging.
Recovery method:
Wait, then retry charging.
Recovery method:
Wait, then retry charging.
Recovery method:
The charger is faulty.
Stop using the charger and contact Projecta support.
Recovery method:
Wait for the plug temperature to drop before retrying.
Check the socket and plug for heat damage before reuse.
Recovery method:
Wait, then retry charging.
Recovery method:
Wait, then retry charging.
Part number: EVC2KW
Power plug: AS/NZS 3112
Cable length: 5m total length
Rated current and power: 10A / 2.4kW
Rated input voltage: 230VAC ±10%
Rated output voltage: 230VAC ±10%
Insulation resistance of cable: >1000MΩ, DC500V
Wiring harness size: 3 x 2.5mm² + 1 x 0.5mm²
Delay start timer: 2h, 4h, 6h, 8h
To maintain the charger:
Store the charger in the storage bag when not in use.
Keep the charger clean and dry.
Inspect the cable, plug and Type 2 connector before use.
Fit the rubber protection cap after use.
Do not store the charger with heavy objects on the cable.
Do not use the charger if the cable, plug, connector or housing is damaged.
Keep the charger away from flammable gases and liquids.
Avoid dropping, crushing or misusing the charger.
Escalate the case if:
The charger repeatedly enters Error Mode.
Error 7 component failure is displayed.
The charger, cable, plug or connector is damaged.
There are signs of overheating, melting, burning smell or discolouration.
The charger trips the supply repeatedly.
RCD / leakage errors continue after retrying.
The charger does not operate according to the manual.
The customer has used an adapter or extension cord and damage is suspected.
Warranty assessment is required.