This article explains how to connect and configure the Projecta PMLVL level sensor on a Compact system. Compact systems do not include a 4-way RJ45 hub by default, so an additional hub must be purchased and installed before the sensor can be connected.
Issue
When attempting to plug the PMLVL level sensor into a free port on the existing 10-way RJ45 hub, the sensor receives no power and does not function.
Root Cause: The PMLVL level sensor requires connection to a 4-way RJ45 hub (not the 10-way hub directly) to receive power. Projecta Compact systems are not supplied with this hub — it must be added separately.
Required Parts
|
Part |
Part Number |
|
PMLVL Level Sensor |
PMLVL |
|
4-Way RJ45 Hub |
IGRJ45HUB-4 |
The PMLVL sensor is available from most major automotive retailers that stock Projecta products, as well as online. The IGRJ45HUB-4 hub can be ordered through the same channels.
Installation Steps
Step 1 — Add the 4-Way Hub
Purchase and install the IGRJ45HUB-4 4-way RJ45 hub.
Step 2 — Rewire the Solar Controller Communications Cable
Step 3 — Connect the 4-Way Hub to the 10-Way Hub
Connect the 4-way hub back into the 10-way hub using the port previously used by the SC540.
Step 4 — Connect the Level Sensor
Plug the PMLVL sensor's RJ45 cable into one of the free ports on the 4-way hub. The sensor should now receive power.
Step 5 — Mount the Sensor
Mount the PMLVL sensor in a central location on the caravan. The sensor can be mounted vertically or horizontally — the orientation is configured in software during calibration.